Test ID PATH1021 Liquid Based Pap Test
Specimen Type/Requirements
Hologic ThinPrep Pap test vial
Note: Excessive blood, carbomer-containing lubricants, and vaginal medications are known to interfere with the processing of the specimen.
Collection Instructions:
1. Label ThinPrep Pap Test vial in presence of patient.
- Must include 2 unique patient identifiers (name, MRN, or DOB) along with the collection date and time.
2. If applicable, use gauze to gently remove blood or mucus from cervix prior to collection.
3. Obtain sample from patient using desired ThinPrep approved collection device.
4. Swish collection device in ThinPrep vial to remove cells from device.
5. Do NOT send collection device in container.
Transportation:
1. Place a properly labeled ThinPrep vial with a secure lid (align the mark on the cap with the line on the vial) in a biohazard transport bag to prevent leakage.
2. Do not place more than one vial in a biohazard bag.
3. All specimens must be submitted with the appropriate Cytology Order.
Specimen Volume
Preferred Volume | ThinPrep Vial |
---|---|
Minimum Volume | ThinPrep Vial |
Note: Do not add or remove fluid from vial.
Stability/Transport
Room Temperature | 3 weeks | Preferred for Transport |
---|---|---|
Refrigerated | Not Acceptable | |
Frozen | Not Acceptable |
Performed Test Frequency
Monday through Friday
Report Available
8 - 10 business days
Methodology
ThinPrep (Imaged or Unimaged)
Performing Lab
Sanford Laboratories Sioux Falls Cytology, Fargo Cytology, and Bismarck Cytology
(Note: Bemidji forwards testing to Fargo Cytology)
CPT
88175 (Imaged), 88142 (Unimaged)
88141 (if Pathologist review is performed)
AKA
Pap, Pap Smear, ThinPrep