Sign in →

Test ID PATH1021 Liquid Based Pap Test

Specimen Type/Requirements

Hologic ThinPrep Pap test vial

Note: Excessive blood, carbomer-containing lubricants, and vaginal medications are known to interfere with the processing of the specimen.

 

Collection Instructions:

1. Label ThinPrep Pap Test vial in presence of patient.

  • Must include 2 unique patient identifiers (name, MRN, or DOB) along with the collection date and time.

2. If applicable, use gauze to gently remove blood or mucus from cervix prior to collection.

3. Obtain sample from patient using desired ThinPrep approved collection device.            

4. Swish collection device in ThinPrep vial to remove cells from device.

5. Do NOT send collection device in container.

 

Transportation:

1. Place a properly labeled ThinPrep vial with a secure lid (align the mark on the cap with the line on the vial) in a biohazard transport bag to prevent leakage.

2. Do not place more than one vial in a biohazard bag.

3. All specimens must be submitted with the appropriate Cytology Order.

Specimen Volume

 Preferred Volume     ThinPrep Vial   
 Minimum Volume     ThinPrep Vial   

Note:  Do not add or remove fluid from vial.

Stability/Transport

 Room Temperature     3 weeks     Preferred for Transport   
 Refrigerated     Not Acceptable     
 Frozen     Not Acceptable  

 

Performed Test Frequency

Monday through Friday

Report Available

8 - 10 business days

Methodology

ThinPrep (Imaged or Unimaged)

Performing Lab

Sanford Laboratories Sioux Falls Cytology, Fargo Cytology, and Bismarck Cytology

(Note: Bemidji forwards testing to Fargo Cytology)

CPT

88175 (Imaged), 88142 (Unimaged)

88141 (if Pathologist review is performed)

 

AKA

Pap, Pap Smear, ThinPrep