Test ID NBLD0553 Amphetamines Confirmation, Random, Urine
Useful For
Confirming drug exposure involving amphetamines such as amphetamine and methamphetamine, phentermine, pseudoephedrine/ephedrine, methylenedioxyamphetamine (MDA), and methylenedioxymethamphetamine (MDMA)
Specimen Type
UrineOrdering Guidance
For situations where chain of custody is required, a Chain of Custody Kit (T282) is available. For chain-of-custody testing, order AMPHX / Amphetamines Confirmation, Chain of Custody, Random, Urine.
Additional drug panels and specific requests are available; call 800-533-1710.
Additional Testing Requirements
If urine creatinine is required or adulteration of the specimen is suspected, the following test should also be ordered, ADULT / Adulterants Survey, Urine.
Specimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube: Plastic urine container
Submission Container/Tube: Plastic, 5-mL tube
Specimen Volume: 3 mL
Collection Instructions:
1. Collect a random urine specimen.
2. No preservative
Additional Information:
1. No specimen substitutions.
2. STAT requests are not accepted for this test.
3. Submitting less than 1 mL will compromise our ability to perform all necessary testing.
Specimen Minimum Volume
1.5 mL
Reject Due To
| Gross hemolysis | OK |
| Gross icterus | OK |
Specimen Stability Information
| Specimen Type | Temperature | Time |
|---|---|---|
| Urine | Refrigerated (preferred) | 28 days |
| Ambient | 28 days | |
| Frozen | 28 days |
Day(s) Performed
Monday through Friday
Report Available
3 to 5 daysMethod Name
Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)
Performing Laboratory
Mayo Clinic Laboratories in Rochester
CPT Code Information
G0480
80325 (if appropriate for select payers(
80359 (if appropriate for select payers)
Reporting Name
Amphetamines Confirmation, UReference Values
Negative
Positive results are reported with a quantitative result.
Cutoff concentrations by liquid chromatography tandem mass spectrometry:
Amphetamine: 25 ng/mL
Methamphetamine: 25 ng/mL
Phentermine: 25 ng/mL
Methylenedioxyamphetamine: 25 ng/mL
Methylenedioxymethamphetamine: 25 ng/mL
Pseudoephedrine/ephedrine: 25 ng/mL reported as negative
Test Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.Secondary ID
8257Forms
If not ordering electronically, complete, print, and send a Therapeutics Test Request (T831) with the specimen.
Special Instructions
SANFORD INTERFACE BUILD INFORMATION
| Result Code | Result Code Description |
|---|---|
| 17368 | Amphetamine-By GC/MS |
| 17369 | Phentermine-By GC/MS |
| 17370 | Methamphetamine-By GC/MS |
| 17371 | Pseudoephedrine/Ephedrine-By GC/MS |
| 17372 | MDA (Ecstasy Metabolite)-By GC/MS |
| 17373 | MDMA (Ecstasy)- By GC/MS |
| 17374 | Interpretation |
| 17375 | Chain of Custody |