Test ID BLOD5059 HLA Solid Organ Transplant Recipient

AKA

Transplant Recipient Workup, New Patient Tissue Typing, Recipient Workup

Specimen Type/Requirements

Draw 3 ACD-B tubes and 2 plain red top tubes. If patient is on dialysis, the blood MUST be drawn pre-dialysis. Keep at room temperature.

Specimen Volume

Preferred Volume 21 mL whole blood (ACD-B) & 14 mL whole blood (Red)
Minimum Volume 3 mL whole blood (ACD-B) & 7 mL whole blood (Red)

 

Stability/Transport

Room Temperature 7 days Preferred for Transport
Refrigerated N/A  
Frozen N/A  

 

Performed Test Frequency

As Needed, Monday through Friday only

Report Available

HLA Typing 14 days
HLA Antibody Screen 31 days
HLA Recipient Flow Crossmatch (AUTO) 3 days

*Once received into performing laboratory.

Additional Information

Panel Includes:

HLA Class I Molecular Typing BLOD1212
HLA Class II Molecular Typing BLOD1213
HLA Antibody Screen: Class I and Class II BLOD5046
HLA Recipient Flow Crossmatch (AUTO) BLOD5095

 

 

 

Methodology

HLA class I and II typing: Reverse Sequence Specific Oligonucleotide Probe (rSSOP) performed on the Luminex Multiplex platform;

Antibody analysis: Luminex microarray Single Antigen beads

 

HLA Recipient Flow Crossmatch (AUTO)- Flow Cytometry

Performing Lab

Sanford Laboratories Fargo- Histocompatibility

CPT

HLA Typing: 81370 (81372 plus 81375); Antibody Analysis: 86832, 86833

 