Test ID BLOD5059 HLA Solid Organ Transplant Recipient
AKA
Transplant Recipient Workup, New Patient Tissue Typing, Recipient Workup
Specimen Type/Requirements
Draw 3 ACD-B tubes and 2 plain red top tubes. If patient is on dialysis, the blood MUST be drawn pre-dialysis. Keep at room temperature.
Specimen Volume
Preferred Volume | 21 mL whole blood (ACD-B) & 14 mL whole blood (Red) |
Minimum Volume | 3 mL whole blood (ACD-B) & 7 mL whole blood (Red) |
Stability/Transport
Room Temperature | 7 days | Preferred for Transport |
Refrigerated | N/A | |
Frozen | N/A |
Performed Test Frequency
As Needed, Monday through Friday only
Report Available
HLA Typing | 14 days |
HLA Antibody Screen | 31 days |
HLA Recipient Flow Crossmatch (AUTO) | 3 days |
*Once received into performing laboratory.
Additional Information
Panel Includes:
HLA Class I Molecular Typing | BLOD1212 |
HLA Class II Molecular Typing | BLOD1213 |
HLA Antibody Screen: Class I and Class II | BLOD5046 |
HLA Recipient Flow Crossmatch (AUTO) | BLOD5095 |
Methodology
HLA class I and II typing: Reverse Sequence Specific Oligonucleotide Probe (rSSOP) performed on the Luminex Multiplex platform;
Antibody analysis: Luminex microarray Single Antigen beads
HLA Recipient Flow Crossmatch (AUTO)- Flow Cytometry
Performing Lab
Sanford Laboratories Fargo- Histocompatibility
CPT
HLA Typing: 81370 (81372 plus 81375); Antibody Analysis: 86832, 86833
HLA Recipient Flow Crossmatch (AUTO): 86825