Sign in →

Test ID BLOD0390 Flecainide, Serum

Useful For

Optimizing flecainide dosage

 

Assessing flecainide toxicity

 

Monitoring compliance

Specimen Type

Serum Red


Specimen Required


Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube: Red top (serum gel/SST are not acceptable)

Submission Container/Tube: Plastic vial

Specimen Volume: 1.5 mL

Collection Instructions:

1. Draw blood immediately before next scheduled dose.

2. Centrifuge and aliquot serum into a plastic vial within 2 hours of collection.


Specimen Minimum Volume

0.5 mL

Reject Due To

Gross hemolysis OK
Gross lipemia OK
Gross icterus OK

Specimen Stability Information

Specimen Type Temperature Time
Serum Red Refrigerated (preferred) 28 days
  Ambient  28 days
  Frozen  28 days

Day(s) Performed

Monday through Friday

Report Available

2 to 5 days

Method Name

Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)

Performing Laboratory

Mayo Clinic Laboratories in Rochester

CPT Code Information

80181

Reporting Name

Flecainide, S

Reference Values

Trough Value

0.2-1.0 mcg/mL: Therapeutic concentration

>1.0 mcg/mL: Toxic concentration

Test Classification

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

Secondary ID

9243

Forms

If not ordering electronically, complete, print, and send a Therapeutics Test Request (T831) with the specimen.

Sanford Laboratories - Fargo Additional Information:

SANFORD INTERFACE BUILD INFORMATION

Result Code Result Code Description
13056 Flecainide, S