Test ID BLOD0379 Factor V (5) Leiden Mutation Analysis

AKA

FVL, Leiden

Specimen Type/Requirements

Lavender top (EDTA) tube - Whole Blood

Lavender top (EDTA) microtainers are also acceptable. 

Specimen tube must NOT have been aliquoted or pierced with instrumentation probes- these will be rejected. 

Specimen Volume

 Preferred Volume     120 uL of Whole Blood   
 Minimum Volume     50 uL of Whole Blood

Stability/Transport

 Room Temperature     24 hours     
 Refrigerated     15 days  
 Frozen     3 months     Preferred for transport   

Performed Test Frequency

Monday through Sunday

Report Available

1 - 3 days

Methodology

Polymerase Chain Reaction

Performing Lab

Sanford Laboratories Fargo- Molecular

CPT

81241

Coverage Limitations

This test has limited coverage - please submit Commercial Insurance Patient Waiver (Non-Medicare) if applicable.