Sign in →

Test ID BLOD0114 von Willebrand Factor Multimer Analysis, Plasma

Useful For

Resolving discrepancies when results of complementary laboratory tests (eg, F8A / Coagulation Factor VIII Activity Assay, Plasma; VWACT / von Willebrand Factor Activity, Plasma; and VWAG / von Willebrand Factor Antigen, Plasma) are abnormally low or discordant

 

Subtyping von Willebrand disease (VWD) (primarily identify variants of type 2 VWD)

 

Aiding in determining appropriate treatment

 

Identifying variants of type 2 VWD that have fewer of the largest multimers, have unusually large multimers, or have qualitatively abnormal "bands" that indicate an abnormal von Willebrand factor structure

Specimen Type

Plasma Na Cit


Ordering Guidance


Coagulation testing is highly complex, often requiring the performance of multiple assays and correlation with clinical information. For that reason, we suggest ordering AVWPR / von Willebrand Disease Profile, Plasma.



Additional Testing Requirements


VWACT / von Willebrand Factor Activity, Plasma and VWAG / von Willebrand Factor Antigen, Plasma are requested but not required before performing this test. If already assayed, submit results. If no results are included, submit separate specimens for the above assays following specimen requirements for each test.



Specimen Required


Specimen Type: Platelet-poor plasma

Patient Preparation:

1. Fasting is preferred.

2. Specimen should be collected prior to coagulation factor replacement therapy.

Collection Container/Tube: Light-blue top (3.2% sodium citrate)

Submission Container/Tube: Plastic vial

Specimen Volume: 1 mL

Collection Instructions:

1. For complete instructions, see Coagulation Guidelines for Specimen Handling and Processing.

2. Centrifuge, transfer all plasma into a plastic vial, and centrifuge plasma again.

3. Aliquot plasma into a plastic vial leaving 0.25 mL in the bottom of centrifuged vial.

4. Freeze plasma immediately (no longer than 4 hours after collection) at -20° C or, ideally, -40° C or below.

Additional Information:

1. Double-centrifuged specimen is critical for accurate results as platelet contamination may cause spurious results.

2. Each coagulation assay requested should have its own vial.


Specimen Minimum Volume

0.5 mL

Reject Due To

Gross hemolysis Reject
Gross lipemia Reject
Gross icterus Reject

Specimen Stability Information

Specimen Type Temperature Time
Plasma Na Cit Frozen 42 days

Day(s) Performed

Monday through Thursday

Report Available

7 to 14 days

Method Name

Agarose Gel Electrophoresis/Infrared Dye-Labeled Antibody Detection

Performing Laboratory

Mayo Clinic Laboratories in Rochester

CPT Code Information

85247

Secondary ID

603851

Reporting Name

von Willebrand Factor Multimer, P

Reference Values

An interpretive report will be provided.

Forms

1. Coagulation Patient Information (T675)

2. If not ordering electronically, complete, print, and send a Coagulation Test Request (T753) with the specimen.

Test Classification

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.
Sanford Laboratories - Fargo Additional Information:

SANFORD LABORATORY INTERFACE BUILD INFORMATION

 Result Code     Result Code Description   
 13718     VonWillebrand Factor Multimer   
 4176     VonWillebrand Factor Multimer Interp